Static testing
A static test ensures that the weight specification stated for the
product has been adequately tested to ensure that the product
is safe to use.
The specific test requirements for the different products,
including the test load and where it must be applied to the
product, are defined in the ISO 17966 standard. A common
feature of these tests is that they must be carried out using a
safety factor of 1.5 in addition to the stated maximum weight
specification and other factors specified in the standard.
Pressalit often chooses to test at higher loads than required by
the standard in order to stress-test the product.
kg
Dynamic testing
A dynamic test ensures that the product has been adequately
tested in relation to its expected service life and the number
of times it is used each day, whether in a private home or an
institutional setting.
The specific test requirements for the different products,
including the test load and the number of cycles the product
must undergo, are defined in the ISO 17966 standard.
A height-adjustable product is moved up and down the
number of times specified by the standard using the calculated
test load. For example, a product with an expected service life
of 10 years that is used by several users every day may need
to be tested for as many as 73,000 cycles.
CE marking
In a Declaration of Conformity, Pressalit declares that the
product complies with applicable legal requirements and that
it has been developed, designed, manufactured and tested in
accordance with applicable standards. The relevant legislation
and standards are stated in the product’s CE Declaration of
Conformity, which can be found on the Pressalit website for the
product in question.
kg